Pumping Stations

Packaged Pumping Solutions

For Single Dwellings & Small Communities

Tricel offers two solutions: a range of single and twin pump chambers. Their capacity ranges from 300L (single option only) to 1,700L (both single and twin pumps available). These packaged pump chambers are used primarily for the transfer of sewage.

Tricel's Virtual Showroom THE LAB

Pumping Stations

Packaged Pumping Solutions

Overview

Packaged Pump Chambers are used to pump fluids from one place to another where gravity drainage cannot be used. They have been designed to ensure an easy and trouble-free installation and are manufactured in high-grade HDPE.

We offer a range of single and twin pump chambers ranging from 300L to 1,700L. You can view the full range below.

These are ideal for single or multiple domestic dwellings. See the list (non-exhaustive) of applications.

Tricel Packaged Pumping Solutions

What are the Tricel Pump Solutions?

Single Pump Chambers

The single package pump stations are designed to collect foul water from an entire property or other buildings which houses multiple people such as commercial offices and other light commercial applications.

The range of pump stations are delivered to site as a complete package, including all internal pipework and one type of sewage pump.

This system also comes with a guide rail and pedestal kit for easy pump access. The station is designed to pump through a 63mm pump main as the chamber’s outlet terminates in a 2” male BSP thread. We would strongly recommend that a high-level alarm is fitted to warn of any issues should they arise.

For detailed instructions for wiring and installation, please review the installation manual.

Tricel Single Pump

Twin Pump Chambers

The twin package pump stations are designed to collect foul water from multiple properties or buildings which houses multiple people such as commercial offices and other medium-sized commercial applications.

The twin range of pump stations are delivered to site as a complete package, including all internal pipework, two sewage pumps, and alternating control panel and float switches.

This system also comes with a guide rail and pedestal kit for easy pump access. The station is designed to pump through a 63mm pump main as the chamber’s outlet terminates in a 2” male BSP thread. A high-level alarm is fitted to warn of any issues should they arise.

For detailed instructions for wiring and installation, please review the installation manual.

Tricel Twin Pump

How does it work?

Packaged Pump Chambers are used to pump fluids from one place to another where a gravity drainage cannot be used.

They collect the effluent or foul water from low-lying developments and pumps to a main sewer or treatment plant. They may also be used to pump from a sewage treatment plant to the raised bed drainage field or watercourse.

Pumping chambers contain:

  • a chamber,
  • a pump,
  • pump controls,
  • float and / or an alarm, based on individual requirements.

Multiple and back-up pumps are also available.

The pump process is controlled with the use of control float which is set to turn on and off at predefined levels.

Available with a single pump from 300 to 1700 litres and as twin pump from 1200 to 1700 litres.

24 hours storage

  • For pump station
  • For pump station + treatment plant 

 

Our pump stations are designed to meet building regulations, including Document H1 (“Foul Drainage”). This stipulates that: “Where foul drainage from a dwelling or building is to be pumped, the effluent receiving chamber should be sized to contain 24 hours inflow to allow for disruptions due to power failures or breakdown. The minimum daily discharge of foul drainage should be taken as 150 litres per day per person for domestic use.”

Download our Brochure and Manual

Discuss your Requirements and Request a Quote

Applications: 

For a single or multiple domestic dwelling, the Tricel packaged pump chambers are used primarily for the transfer of sewage from:

  • A dwelling to a Tricel Sewage Treatment System at a raised location.
  • Multiple domestic dwellings to a main sewer or treatment systems.

 

Other applications include:

  • Discharging to the mains where gravity is not possible.
  • Pumping sewage, surface water, or rainwater to the mains.
  • Pumping effluent from septic tanks or wastewater treatment plants to a watercourse or a drainage field.
  • Suitable for domestic housing, light commercial, and industrial properties.

Key features & benefits of our Packaged Pumping Solutions:  

 

  • Simple, reliable solution
  • Easy to install. Simple control panel
  • Low maintenance & high longevity. No mechanical moving parts
  • Lightweight, made of HDPE
  • Suitable for raw sewage and final effluent
  • Single and twin pump options available
  • Non-return valves included
  • Flexible invert levels. Inlet to be drilled to suit site conditions.
  • 1m Dia + systems come with stiffening ribbing to the base and surround for added durability.
Outlet is fixed
  • Ribbing also allows for a unique pump mounting system which eliminates the need for fixings to be made through the base, allowing easy remedials 10-15 years down the line.
Ribbins

Pump Chamber dimensions

See below our range of Packaged Pumping Solutions. 

Pump Chamber CapacityPump OptionHeightDiameterAccess Cover SizeAccess Cover Rating
300LSingle Option Only1000mm610mm450mm DiaPedestrian
450LSingle Option Only1500mm610mm450mm DiaPedestrian
600LSingle Option Only2000mm610mm450mm DiaPedestrian
1200LSingle and Twin Pumps1500mm1000mm600x600mm DiaPedestrian
1700LSingle and Twin Pumps2000mm1000mm600x600mm DiaPedestrian

Pump Technical Data 

See below the pump technical data table & graph.

CharacteristicsPump Option 1Pump Option 2
Model ref10VXMC
Impeller TypeVortexMacerator
Power Supply230 ~ 1ph ~ 50hz
Power rated0.75kw1.2kW
Rated Current4.0A9.2A
Max Head10m16m
Max Flow Rate7.9 I/s1.8 I/s
Cable Length10m10m
Free Passage50mmMacerator

Pump Drawings

1700L Package Pump Solution, available as single and twin.

Pump drawing 1700L Package Pump Solution

300L Package Pump Solution

Pump drawing 300L Package Pump Solution

Other Pumping Stations available

Also available from Tricel are our Pumping Stations. Constructed from GRP, we manufacture 1,000-litre and 1,600-litre standard domestic pump stations in accordance with the building regulations.

The Tricel packaged sewage pumping stations contain:

  • Underground tank made from GRP (Glass Reinforced Polymer)
  • Inlet point
  • Outlet point
  • Submersible pump
  • Control panel and alarm

If you have any questions or require information, please get in touch with us. You can also download the brochure and manual. 

Discuss your Requirements and Request a Quote

Download our Brochure and Manual

Key Features
Custom designed

Custom-designed

At Tricel we also design tailored sewage pumping stations to suit our customers’ specific requirements.

Robust

Robust

Our sewage pumping stations are lightweight and highly durable.

Certified

Certified

Our pump stations are designed to meet building regulations, including Document H1 (“Foul Drainage”).

Get in touch

Tricel Environment UK

A trading brand of Dewey Waters Ltd.
Heritage Works, Winterstoke Road, Weston-super-Mare, BS24 9AN, United Kingdom.
Tel: +44 (0)1934 422 311